Følg
Jonathan Newell
Jonathan Newell
Professor of Biomedical Engineering, Rensselaer Polytechnic Institute
Verificeret mail på rpi.edu
Titel
Citeret af
Citeret af
År
Electrical impedance tomography
M Cheney, D Isaacson, JC Newell
SIAM review 41 (1), 85-101, 1999
14871999
NOSER: An algorithm for solving the inverse conductivity problem
M Cheney, D Isaacson, JC Newell, S Simske, J Goble
International Journal of Imaging systems and technology 2 (2), 66-75, 1990
8051990
Electrode models for electric current computed tomography
KS Cheng, D Isaacson, JC Newell, DG Gisser
IEEE Transactions on Biomedical Engineering 36 (9), 918-924, 1989
7191989
Bi-level charge pulse apparatus to facilitate nerve location during peripheral nerve block procedures
RL Griffith, RJ Strowe, JC Newell, PM Edic, RF Messina, FC Houghton
US Patent 5,853,373, 1998
4641998
Modeling and analysis of dynamic systems
CM Close, DK Frederick, JC Newell
John Wiley & Sons, 2001
4472001
ACT3: a high-speed, high-precision electrical impedance tomograph
RD Cook, GJ Saulnier, DG Gisser, JC Goble, JC Newell, D Isaacson
IEEE Transactions on Biomedical Engineering 41 (8), 713-722, 1994
2971994
Bi-level charge pulse apparatus to facilitate nerve location during peripheral nerve block procedures
RL Griffith, RJ Strowe, JC Newell, PM Edic, RF Messina, FC Houghton
US Patent 6,325,764, 2001
2532001
Current source design for electrical impedance tomography
AS Ross, GJ Saulnier, JC Newell, D Isaacson
Physiological measurement 24 (2), 509, 2003
2222003
Reconstructions of chest phantoms by the D-bar method for electrical impedance tomography
D Isaacson, JL Mueller, JC Newell, S Siltanen
IEEE Transactions on medical imaging 23 (7), 821-828, 2004
2142004
Electrical impedance tomography
GJ Saulnier, RS Blue, JC Newell, D Isaacson, PM Edic
IEEE Signal Processing Magazine 18 (6), 31-43, 2001
1992001
Electric current computed tomography and eigenvalues
DG Gisser, D Isaacson, JC Newell
SIAM Journal on Applied Mathematics 50 (6), 1623-1634, 1990
1951990
Regression of calculated variables in the presence of shared measurement error
HH Stratton, PJ Feustel, JC Newell
Journal of Applied Physiology 62 (5), 2083-2093, 1987
1871987
An electric current tomograph
JC Newell, DG Gisser, D Isaacson
IEEE Transactions on Biomedical Engineering 35 (10), 828-833, 1988
1861988
A reconstruction algorithm for electrical impedance tomography data collected on rectangular electrode arrays
JL Mueller, D Isaacson, JC Newell
IEEE Transactions on Biomedical Engineering 46 (11), 1379-1386, 1999
1781999
Current topics in impedance imaging
DG Gisser, D Isaacson, JC Newell
Clinical Physics and Physiological Measurement 8 (4A), 39, 1987
1781987
Influence of hematocrit on cardiopulmonary function after acute hemorrhage
JB FORTUNE, PJ FEUSTEL, J SAIFI, HH STRATTON, JC NEWELL, ...
Journal of Trauma and Acute Care Surgery 27 (3), 243-249, 1987
1411987
Imaging cardiac activity by the D-bar method for electrical impedance tomography
D Isaacson, JL Mueller, JC Newell, S Siltanen
Physiological Measurement 27 (5), S43, 2006
1302006
A real-time electrical impedance tomograph
PM Edic, GJ Saulnier, JC Newell, D Isaacson
IEEE Transactions on Biomedical Engineering 42 (9), 849-859, 1995
1281995
Failure of red blood cell transfusion to increase oxygen transport or mixed venous PO2 in injured patients
DM SHAH, ME GOTTLIEB, RL RAHM, HH STRATTON, PS BARIE, ...
Journal of Trauma and Acute Care Surgery 22 (9), 741-746, 1982
1271982
Indocyanine green: Its use as an early indicator of hepatic dysfunction following injury in man
ME Gottlieb, HH Stratton, JC Newell, DM Shah
Archives of surgery 119 (3), 264-268, 1984
1261984
Systemet kan ikke foretage handlingen nu. Prøv igen senere.
Artikler 1–20