Følg
Robert S Armiger
Robert S Armiger
Johns Hopkins University Applied Physics Laboratory
Verificeret mail på jhuapl.edu
Titel
Citeret af
Citeret af
År
Individual finger control of a modular prosthetic limb using high-density electrocorticography in a human subject
G Hotson, DP McMullen, MS Fifer, MS Johannes, KD Katyal, MP Para, ...
Journal of neural engineering 13 (2), 026017, 2016
2412016
Intraoperative image-based multiview 2D/3D registration for image-guided orthopaedic surgery: incorporation of fiducial-based C-arm tracking and GPU-acceleration
Y Otake, M Armand, RS Armiger, MD Kutzer, E Basafa, P Kazanzides, ...
IEEE transactions on medical imaging 31 (4), 948-962, 2011
1572011
A new interpretation of the mechanism of ankle fracture
N Haraguchi, RS Armiger
JBJS 91 (4), 821-829, 2009
1192009
Virtual interactive musculoskeletal system (VIMS) in orthopaedic research, education and clinical patient care
EYS Chao, RS Armiger, H Yoshida, J Lim, N Haraguchi
Journal of Orthopaedic Surgery and Research 2, 1-19, 2007
1052007
Three-dimensional mechanical evaluation of joint contact pressure in 12 periacetabular osteotomy patients with 10-year follow-up
RS Armiger, M Armand, K Tallroth, J Lepistö, SC Mears
Acta orthopaedica 80 (2), 155-161, 2009
982009
Prediction of three-dimensional contact stress and ligament tension in the ankle during stance determined from computational modeling
N Haraguchi, RS Armiger, MS Myerson, JT Campbell, EYS Chao
Foot & ankle international 30 (2), 177-185, 2009
692009
Air-Guitar Hero: a real-time video game interface for training and evaluation of dexterous upper-extremity neuroprosthetic control algorithms
RS Armiger, RJ Vogelstein
2008 IEEE Biomedical Circuits and Systems Conference, 121-124, 2008
602008
Conveying tactile feedback in sensorized hand neuroprostheses using a biofidelic model of mechanotransduction
SS Kim, AP Sripati, RJ Vogelstein, RS Armiger, AF Russell, SJ Bensmaia
IEEE transactions on biomedical circuits and systems 3 (6), 398-404, 2009
542009
Patient-specific finite element modeling for femoral bone augmentation
E Basafa, RS Armiger, MD Kutzer, SM Belkoff, SC Mears, M Armand
Medical engineering & physics 35 (6), 860-865, 2013
482013
Targeted transcutaneous electrical nerve stimulation for phantom limb sensory feedback
L Osborn, M Fifer, C Moran, J Betthauser, R Armiger, R Kaliki, N Thakor
2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2017
472017
Initial clinical evaluation of the modular prosthetic limb
BN Perry, CW Moran, RS Armiger, PF Pasquina, JW Vandersea, JW Tsao
Frontiers in neurology 9, 153, 2018
402018
Evaluation of a computerized measurement technique for joint alignment before and during periacetabular osteotomy
RS Armiger, M Armand, J Lepisto, D Minhas, K Tallroth, SC Mears, ...
Computer aided surgery 12 (4), 215-224, 2007
402007
Use of a virtual integrated environment in prosthetic limb development and phantom limb pain
AL Alphonso, BT Monson, MJ Zeher, RS Armiger, SR Weeks, JM Burck, ...
Annual Review of Cybertherapy and Telemedicine 2012, 305-309, 2012
382012
WiiEMG: A real-time environment for control of the Wii with surface electromyography
H Oppenheim, RS Armiger, RJ Vogelstein
Proceedings of 2010 IEEE International Symposium on Circuits and Systems …, 2010
382010
Development of a biomechanical guidance system for periacetabular osteotomy
RJ Murphy, RS Armiger, J Lepistö, SC Mears, RH Taylor, M Armand
International journal of computer assisted radiology and surgery 10, 497-508, 2015
372015
Clinical trial of the virtual integration environment to treat phantom limb pain with upper extremity amputation
BN Perry, RS Armiger, M Wolde, KA McFarland, AL Alphonso, BT Monson, ...
Frontiers in neurology 9, 770, 2018
352018
The modular prosthetic limb
MS Johannes, EL Faulring, KD Katyal, MP Para, JB Helder, A Makhlin, ...
Wearable robotics, 393-444, 2020
322020
Enabling closed-loop control of the modular prosthetic limb through haptic feedback
RS Armiger, FV Tenore, KD Katyal, MS Johannes, A Makhlin, ML Natter, ...
Johns Hopkins APL Technical Digest (Applied Physics Laboratory) 31 (4), 345-353, 2013
322013
A real-time virtual integration environment for neuroprosthetics and rehabilitation
RS Armiger, FV Tenore, WE Bishop, JD Beaty, MM Bridges, JM Burck, ...
Johns Hopkins APL Technical Digest 30 (3), 198-206, 2011
302011
Sensory stimulation enhances phantom limb perception and movement decoding
LE Osborn, K Ding, MA Hays, R Bose, MM Iskarous, A Dragomir, Z Tayeb, ...
Journal of neural engineering 17 (5), 056006, 2020
292020
Systemet kan ikke foretage handlingen nu. Prøv igen senere.
Artikler 1–20