Follow
Ranjith Wijesinghe
Ranjith Wijesinghe
Professor of Physics
Verified email at bsu.edu
Title
Cited by
Cited by
Year
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
E Donchin, KM Spencer, R Wijesinghe
IEEE transactions on rehabilitation engineering 8 (2), 174-179, 2000
17202000
EEG coherency: I: statistics, reference electrode, volume conduction, Laplacians, cortical imaging, and interpretation at multiple scales
PL Nunez, R Srinivasan, AF Westdorp, RS Wijesinghe, DM Tucker, ...
Electroencephalography and clinical neurophysiology 103 (5), 499-515, 1997
15441997
A theoretical and experimental study of high resolution EEG based on surface Laplacians and cortical imaging
PL Nunez, RB Silberstein, PJ Cadusch, RS Wijesinghe, AF Westdorp, ...
Electroencephalography and clinical neurophysiology 90 (1), 40-57, 1994
4941994
EEG coherency II: experimental comparisons of multiple measures
PL Nunez, RB Silberstein, Z Shi, MR Carpenter, R Srinivasan, DM Tucker, ...
Clinical neurophysiology 110 (3), 469-486, 1999
4161999
High-resolution EEG using spline generated surface Laplacians on spherical and ellipsoidal surfaces
SK Law, PL Nunez, RS Wijesinghe
IEEE transactions on Biomedical engineering 40 (2), 145-153, 1993
2171993
The activating function for magnetic stimulation derived from a three-dimensional volume conductor model
PJ Basser, RS Wijesinghe, BJ Roth
IEEE transactions on biomedical engineering 39 (11), 1207-1210, 1992
831992
Instrumentation and techniques for high-resolution magnetic imaging
JP Wikswo Jr, J van Egeraat, YP Ma, NG Sepulveda, DJ Staton, S Tan, ...
Digital Image Synthesis and Inverse Optics 1351, 438-470, 1990
601990
A model for compound action potentials and currents in a nerve bundle I: The forward calculation
RS Wijesinghe, FLH Gielen, JP Wikswo
Annals of biomedical engineering 19, 43-72, 1991
591991
A model for compound action potentials and currents in a nerve bundle III: A comparison of the conduction velocity distributions calculated from compound action currents and …
RS Wijesinghe, FLH Gielen, JP Wikswo
Annals of biomedical engineering 19, 97-121, 1991
451991
Comparison of high resolution EEG methods having different theoretical bases
PL Nunez, RB Silberstein, PJ Cadusch, R Wijesinghe
Brain Topography 5, 361-364, 1993
321993
Magnetic measurements of peripheral nerve function using a neuromagnetic current probe
RS Wijesinghe
Experimental Biology and Medicine 235 (2), 159-169, 2010
242010
Spatial filter approach for comparison of the forward and inverse problems of electroencephalography and magnetoencephalography
LA Bradshaw, RS Wijesinghe, JP Wikswo
Annals of Biomedical Engineering 29, 214-226, 2001
232001
A model for compound action potentials and currents in a nerve bundle II: A sensitivity analysis of model parameters for the forward and inverse calculations
RS Wijesinghe, JP Wikswo
Annals of biomedical engineering 19, 73-96, 1991
221991
Intraoperative recording of the magnetic field of a human nerve
JP Wikswo, WP Henry, RN Friedman, AW Kilroy, RS Wijesinghe, ...
Advances in biomagnetism, 137-140, 1989
221989
A dipole model for spreading cortical depression
N Tepley, RS Wijesinghe
Brain Topography 8 (4), 345-353, 1996
211996
Magnetic stimulation of axons in a nerve bundle: effects of current redistribution in the bundle
SS Nagarajan, DM Durand, BJ Roth, RS Wijesinghe
Annals of biomedical engineering 23, 116-126, 1995
191995
Detection of peripheral nerve and skeletal muscle action currents using magnetic resonance imaging
RS Wijesinghe, BJ Roth
Annals of biomedical engineering 37, 2402-2406, 2009
182009
Detection of magnetic fields created by biological tissues
RS Wijesinghe
Journal of Electrical and Electronic Systems 3, 1-7, 2014
142014
Is it possible to detect dendrite currents using presently available magnetic resonance imaging techniques?
WI Jay, RS Wijesinghe, BD Dolasinski, BJ Roth
Medical & biological engineering & computing 50, 651-657, 2012
142012
Lorentz effect imaging of ionic currents in solution using correct values for ion mobility
RS Wijesinghe, BJ Roth
Journal of magnetic resonance 204 (2), 225-227, 2010
132010
The system can't perform the operation now. Try again later.
Articles 1–20