Følg
Marco Ballini
Marco Ballini
Verificeret mail på imec.be
Titel
Citeret af
Citeret af
År
Switch-matrix-based high-density microelectrode array in CMOS technology
U Frey, J Sedivy, F Heer, R Pedron, M Ballini, J Mueller, D Bakkum, ...
IEEE Journal of Solid-State Circuits 45 (2), 467-482, 2010
2892010
High-resolution CMOS MEA platform to study neurons at subcellular, cellular, and network levels
J Müller, M Ballini, P Livi, Y Chen, M Radivojevic, A Shadmani, V Viswam, ...
Lab on a Chip 15 (13), 2767-2780, 2015
2792015
A 1024-channel CMOS microelectrode array with 26,400 electrodes for recording and stimulation of electrogenic cells in vitro
M Ballini, J Müller, P Livi, Y Chen, U Frey, A Stettler, A Shadmani, ...
IEEE journal of solid-state circuits 49 (11), 2705-2719, 2014
2372014
A Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 m SOI CMOS
CM Lopez, J Putzeys, BC Raducanu, M Ballini, S Wang, A Andrei, ...
IEEE transactions on biomedical circuits and systems 11 (3), 510-522, 2017
1912017
Time multiplexed active neural probe with 1356 parallel recording sites
BC Raducanu, RF Yazicioglu, CM Lopez, M Ballini, J Putzeys, S Wang, ...
Sensors 17 (10), 2388, 2017
1622017
A 966-electrode neural probe with 384 configurable channels in 0.13µm SOI CMOS
CM Lopez, S Mitra, J Putzeys, B Raducanu, M Ballini, A Andrei, S Severi, ...
2016 IEEE International Solid-State Circuits Conference (ISSCC), 392-393, 2016
892016
Time multiplexed active neural probe with 678 parallel recording sites
BC Raducanu, RF Yazicioglu, CM Lopez, M Ballini, J Putzeys, S Wang, ...
2016 46th European Solid-State Device Research Conference (ESSDERC), 385-388, 2016
552016
Why not record from every electrode with a CMOS scanning probe?
G Dimitriadis, JP Neto, A Aarts, A Alexandru, M Ballini, F Battaglia, ...
BioRxiv, 275818, 2018
272018
Leakage compensation scheme for ultra‐high‐resistance pseudo‐resistors in neural amplifiers
S Wang, CM Lopez, M Ballini, N Van Helleputte
Electronics letters 54 (5), 270-272, 2018
212018
A 1024-channel CMOS microelectrode-array system with 26'400 electrodes for recording and stimulation of electro-active cells in-vitro
M Ballini, J Mueller, P Livi, Y Chen, U Frey, A Shadmani, IL Jones, ...
2013 Symposium on VLSI Circuits, C54-C55, 2013
212013
Ultra-thin biocompatible implantable chip for bidirectional communication with peripheral nerves
MO de Beeck, R Verplancke, D Schaubroeck, D Cuypers, M Cauwe, ...
2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), 1-4, 2017
192017
A 108 dB DR Δ∑-∑M Front-End With 720 mVpp Input Range and >±300 mV Offset Removal for Multi-Parameter Biopotential Recording
X Yang, J Xu, M Ballini, H Chun, M Zhao, X Wu, C Van Hoof, CM Lopez, ...
IEEE Transactions on Biomedical Circuits and Systems 15 (2), 199-209, 2021
18*2021
Development of an active high-density transverse intrafascicular micro-electrode probe
R Verplancke, M Cauwe, D Schaubroeck, D Cuypers, B Vandecasteele, ...
Journal of Micromechanics and Microengineering 30 (1), 015010, 2019
182019
A compact, low-power analog front-end with event-driven input biasing for high-density neural recording in 22-nm FDSOI
X Huang, M Ballini, S Wang, B Miccoli, C Van Hoof, G Gielen, J Craninckx, ...
IEEE Transactions on Circuits and Systems II: Express Briefs 69 (3), 804-808, 2021
162021
Intraneural active probe for bidirectional peripheral nerve interface
M Ballini, J Bae, N Marrocco, R Verplancke, D Schaubroeck, D Cuypers, ...
2017 Symposium on VLSI Circuits, C50-C51, 2017
162017
Depth recording capabilities of planar high-density microelectrode arrays
U Frey, U Egert, D Jackel, J Sedivy, M Ballini, P Livi, F Faraci, F Heer, ...
2009 4th International IEEE/EMBS Conference on Neural Engineering, 207-210, 2009
162009
A compact chopper stabilized Δ-ΔΣ neural readout IC with input impedance boosting
S Wang, M Ballini, X Yang, C Sawigun, JW Weijers, D Biswas, ...
IEEE Open Journal of the Solid-State Circuits Society 1, 67-78, 2021
152021
A 108dB DR Hybrid-CTDT Direct-Digitalization ΔΣ-ΣM Front-End with 720mVpp Input Range and >300mV Offset Removal for Wearable Bio-Signal Recording
X Yang, J Xu, H Chun, M Ballini, M Zhao, X Wu, C Van Hoof, ...
2019 Symposium on VLSI Circuits, C296-C297, 2019
152019
A 77-dB DR 16-Ch 2nd-order Δ-ΔΣ Neural Recording Chip with 0.0077mm2/Ch
S Wang, M Ballini, X Yang, C Sawigun, JW Weijers, D Biswas, CM Lopez
2021 Symposium on VLSI Circuits, 1-2, 2021
142021
Actively multiplexed μECoG brain implant system with incremental-ΔΣ ADCs employing bulk-DACs
X Huang, H Londoño-Ramírez, M Ballini, C Van Hoof, J Genoe, S Haesler, ...
IEEE Journal of Solid-State Circuits 57 (11), 3312-3323, 2022
132022
Systemet kan ikke foretage handlingen nu. Prøv igen senere.