Comparison of existing electrode designs for preferential activation of cutaneous nociceptors AH Poulsen, J Tigerholm, S Meijs, OK Andersen, CD Mørch Journal of neural engineering 17 (3), 036026, 2020 | 45 | 2020 |
Electrochemical properties of titanium nitride nerve stimulation electrodes: an in vitro and in vivo study S Meijs, M Fjorback, C Jensen, S Sørensen, K Rechendorff, NJM Rijkhoff Frontiers in neuroscience 9, 268, 2015 | 33 | 2015 |
Biofouling resistance of boron-doped diamond neural stimulation electrodes is superior to titanium nitride electrodes in vivo S Meijs, M Alcaide, C Sørensen, M McDonald, S Sørensen, K Rechendorff, ... Journal of neural engineering 13 (5), 056011, 2016 | 26 | 2016 |
Influence of fibrous encapsulation on electro-chemical properties of TiN electrodes S Meijs, M Fjorback, C Jensen, S Sørensen, K Rechendorff, NJM Rijkhoff Medical engineering & physics 38 (5), 468-476, 2016 | 14 | 2016 |
Influence of implantation on the electrochemical properties of smooth and porous TiN coatings for stimulation electrodes S Meijs, C Sørensen, S Sørensen, K Rechendorff, M Fjorback, ... Journal of neural engineering 13 (2), 026011, 2016 | 14 | 2016 |
Diamond/porous titanium nitride electrodes with superior electrochemical performance for neural interfacing S Meijs, M McDonald, S Sørensen, K Rechendorff, L Fekete, L Klimša, ... Frontiers in bioengineering and biotechnology 6, 171, 2018 | 13 | 2018 |
The Use of the Velocity Selective Recording Technique to Reveal the Excitation Properties of the Ulnar Nerve in Pigs FR Andreis, B Metcalfe, TAM Janjua, W Jensen, S Meijs, ... Sensors 22 (1), 58, 2021 | 10 | 2021 |
The effect of peripheral high-frequency electrical stimulation on the primary somatosensory cortex in pigs TAM Janjua, TGN dos Santos Nielsen, FR Andreis, S Meijs, W Jensen IBRO neuroscience reports 11, 112-118, 2021 | 7 | 2021 |
A systematic review of porcine models in translational pain research S Meijs, M Schmelz, S Meilin, W Jensen Lab animal 50 (11), 313-326, 2021 | 6 | 2021 |
Increased Charge Storage Capacity of Titanium Nitride Electrodes by Deposition of Boron-doped Nanocrystalline Diamond Films. S Meijs, M McDonald, S Sørensen, K Rechendorff, V Petrák, M Nesladek, ... NEUROTECHNIX, 106-109, 2015 | 6 | 2015 |
Comparison of the electrochemical properties of smooth and porous TiN electrode coatings in rats S Meijs, C Sørensen, S Sørensen, K Rechendorff, M Fjorback, ... 2015 7th International IEEE/EMBS Conference on Neural Engineering (NER), 486-489, 2015 | 6 | 2015 |
Increasing voltage transients using implanted titanium nitride neural stimulation electrodes S Meijs, M Fjorback, S Sørensen, K Rechendorff, NJM Rijkhoff Replace, Repair, Restore, Relieve–Bridging Clinical and Engineering …, 2014 | 6 | 2014 |
Electrochemical characterization of boron-doped nanocrystalline diamond electrodes for neural stimulation S Meijs, A Taylor, CP Pennisi, NJM Rijkhoff 6th Annual International IEEE EMBS Conference on Neural Engineering (San …, 2013 | 6 | 2013 |
Chronic Electrochemical Investigation of Titanium Nitride Stimulation Electrodes in vivo S Meijs, M Fjorback, NJM Rijkhoff Converging clinical and engineering research on neurorehabilitation, 421-425, 2012 | 5 | 2012 |
Biocompatibility and electrochemical assessment of boron doped nanocrystalline diamond electrodes for neural stimulation CP Pennisi, M Alcaide, S Papaioannou, S Meijs, A Taylor, M Nesladek, ... Front. Neuroeng. Conference Abstract: MERIDIAN 30M Workshop (Brixen), 2014 | 2 | 2014 |
Morphology and morphometry of the ulnar nerve in the forelimb of pigs FR Andreis, B Metcalfe, TAM Janjua, VPS Fazan, W Jensen, S Meijs, ... Anatomia, histologia, embryologia 53 (1), e12972, 2024 | 1 | 2024 |
On determining the mechanical nociceptive threshold in pigs: a reliability study F Rettore Andreis, CD Mørch, W Jensen, S Meijs Frontiers in Pain Research 4, 1191786, 2023 | 1 | 2023 |
A Comparison of Delay-and-Add and Maximum Likelihood Estimation for Velocity-Selective Recording Using Multi-Electrode Cuffs FR Andreis, B Metcalfe, TAM Janjua, S Meijs, MA Favretto, W Jensen, ... 2022 44th Annual International Conference of the IEEE Engineering in …, 2022 | 1 | 2022 |
The pro-algesic effect of γ-aminobutyric acid (GABA) injection into the masseter muscle of healthy men and women S Meijs, S Liao, L Arendt-Nielsen, K Wang, BE Cairns Scandinavian Journal of Pain 20 (1), 139-150, 2020 | 1 | 2020 |
Corrosion Study of Implanted TiN Electrodes Using Excessive Electrical Stimulation in Minipigs S Meijs, K Rechendorff, S Sørensen, NJM Rijkhoff Metals 9 (4), 389, 2019 | 1 | 2019 |