Follow
Arjan Buis
Arjan Buis
Biomedical Engineering
Verified email at strath.ac.uk
Title
Cited by
Cited by
Year
Dynamic interface pressure distributions of two transtibial prosthetic socket concepts.
T Dumbleton, AW Buis, A McFadyen, BF McHugh, G McKay, KD Murray, ...
Journal of Rehabilitation Research & Development 46 (3), 2009
1312009
Calibration problems encountered while monitoring stump/socket interface pressures with force sensing resistors: techniques adopted to minimise inaccuracies
AWP Buis, P Convery
Prosthetics and orthotics international 21 (3), 179-182, 1997
1221997
Comparison of adaptive neuro-fuzzy inference system (ANFIS) and Gaussian processes for machine learning (GPML) algorithms for the prediction of skin temperature in lower limb …
N Mathur, I Glesk, A Buis
Medical engineering & physics 38 (10), 1083-1089, 2016
1162016
Socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a trans-tibial amputee wearing a hydrocast socket
P Convery, AWP Buis
Prosthetics and Orthotics International 23 (2), 107-112, 1999
901999
Conventional patellar-tendon-bearing (PTB) socket/stump interface dynamic pressure distributions recorded during the prosthetic stance phase of gait of a transtibial amputee
P Convery, AWP Buis
Prosthetics and orthotics international 22 (3), 193-198, 1998
791998
Provision of prosthetic and orthotic services in low-income countries: A review of the literature
CS Harkins, A McGarry, A Buis
Prosthetics and Orthotics International 37 (5), 353-361, 2013
762013
Skin temperature prediction in lower limb prostheses
N Mathur, I Glesk, A Buis
IEEE Journal of Biomedical and Health informatics 20 (1), 158-165, 2014
582014
The aesthetic appeal of prosthetic limbs and the uncanny valley: The role of personal characteristics in attraction
S Sansoni, A Wodehouse, AK McFadyen, A Buis
International Journal of Design 9 (1), 67-81, 2015
472015
Magnetic resonance imaging technology in transtibial socket research: a pilot study
AWP Buis, B Condon, D Brennan, B McHugh, D Hadley
Journal of rehabilitation research and development 43 (7), 883, 2006
402006
The effect of alignment changes on unilateral transtibial amputee’s gait: a systematic review
N Jonkergouw, MR Prins, AWP Buis, P Wurff
Plos one 11 (12), e0167466, 2016
362016
A practical gait feedback method based on wearable inertial sensors for a drop foot assistance device
L Meng, U Martinez-Hernandez, C Childs, AA Dehghani-Sanij, A Buis
IEEE Sensors Journal 19 (24), 12235-12243, 2019
312019
Measurement of the consistency of patellar‐tendon‐bearing cast rectification
P Convery, AWP Buis, R Wilkie, S Sockalingam, A Blair, B McHugh
Prosthetics and orthotics international 27 (3), 207-213, 2003
312003
Evaluation of the effect of shape on a contemporary CAD system
T McGarry, B McHugh, A Buis, G McKay
Prosthetics and orthotics international 32 (2), 145-154, 2008
302008
A practical design and implementation of a low cost platform for remote monitoring of lower limb health of amputees in the developing world
N Mathur, G Paul, J Irvine, M Abuhelala, A Buis, I Glesk
IEEE Access 4, 7440-7451, 2016
292016
Toward novel wearable pyroelectric temperature sensor for medical applications
A Davidson, A Buis, I Glesk
IEEE Sensors Journal 17 (20), 6682-6689, 2017
272017
Hands-off and hands-on casting consistency of amputee below knee sockets using magnetic resonance imaging
MR Safari, P Rowe, A McFadyen, A Buis
The Scientific World Journal 2013, 2013
262013
Measuring the daily stepping activity of people with transtibial amputation using the ActivPAL™ activity monitor
AWP Buis, T Dumbleton, KD Murray, BF McHugh, G McKay, S Sexton
JPO: Journal of Prosthetics and Orthotics 26 (1), 43-47, 2014
252014
Nitinol for prosthetic and orthotic applications
E Henderson, A Buis
Journal of materials engineering and performance 20, 663-665, 2011
242011
Pilot study: Data‐capturing consistency of two trans‐tibial casting concepts, using a manikin stump model: A comparison between the hands‐on PTB and hands‐off ICECAST compact …
AWP Buis, A Blair, P Convery, S Sockalingam, B McHugh
Prosthetics and Orthotics International 27 (2), 100-106, 2003
222003
Cross cultural equivalence testing of the Prosthetic Evaluation Questionnaire (PEQ) for an Arabic speaking population
SJ Day, A Buis
Prosthetics and Orthotics International 36 (2), 173-180, 2012
202012
The system can't perform the operation now. Try again later.
Articles 1–20