Follow
Matthew R. Morgan
Matthew R. Morgan
Verified email at alumni.duke.edu
Title
Cited by
Cited by
Year
Chronic intrauterine pulmonary hypertension increases main pulmonary artery stiffness and adventitial remodeling in fetal sheep
RB Dodson, MR Morgan, C Galambos, KS Hunter, SH Abman
American Journal of Physiology-Lung Cellular and Molecular Physiology 307 …, 2014
372014
Versatile low-cost volumetric 3-D ultrasound platform for existing clinical 2-D systems
MR Morgan, JS Broder, JJ Dahl, CD Herickhoff
IEEE transactions on medical imaging 37 (10), 2248-2256, 2018
352018
Low-cost volumetric ultrasound by augmentation of 2D systems: Design and prototype
CD Herickhoff, MR Morgan, JS Broder, JJ Dahl
Ultrasonic imaging 40 (1), 35-48, 2018
322018
Multi-covariate imaging of sub-resolution targets
MR Morgan, GE Trahey, WF Walker
IEEE transactions on medical imaging 38 (7), 1690-1700, 2019
242019
Evaluation of large-aperture imaging through the ex vivo human abdominal wall
N Bottenus, W Long, M Morgan, G Trahey
Ultrasound in medicine & biology 44 (3), 687-701, 2018
222018
Synthetic aperture focusing for multi-covariate imaging of sub-resolution targets
MR Morgan, N Bottenus, GE Trahey, WF Walker
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 67 …, 2020
82020
Speckle coherence of piecewise-stationary stochastic targets
MR Morgan, GE Trahey, WF Walker
The Journal of the Acoustical Society of America 146 (3), 1721-1731, 2019
82019
3d ultrasound imaging, associated methods, devices, and systems
CD Herickhoff, JJ Dahl, JS Broder, MR Morgan
US Patent App. 15/735,024, 2018
82018
Intrinsic tradeoffs in multi-covariate imaging of sub-resolution targets
MR Morgan, GE Trahey, WF Walker
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 67 …, 2020
32020
Oriented 3D ultrasound for central venous cannulation using an augmented 2D ultrasound system
JS Broder, MR Morgan, EJ Jaffa, RG Theophanous
Academic Emergency Medicine 26 (10), 1173-1176, 2019
32019
Short-lag spatial coherence imaging in 1.5-d and 1.75-d arrays: Elevation performance and array design considerations
MR Morgan, D Hyun, GE Trahey
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 66 …, 2019
32019
Methods, systems and computer program products for ultrasound imaging using coherence contribution
W Walker, M Morgan, G Trahey
US Patent App. 17/284,860, 2021
22021
Adaptive models for multi-covariate imaging of sub-resolution targets (MIST)
R Ahmed, KM Flint, MR Morgan, GE Trahey, WF Walker
IEEE transactions on ultrasonics, ferroelectrics, and frequency control 69 …, 2022
12022
212 3d volume ultrasound of the right lower quadrant for diagnosis of appendicitis
JS Broder, E Jaffa, T Irons, E Peethumnongsin, R Theophanous, ...
Annals of Emergency Medicine 72 (4), S85, 2018
12018
394 Brain Imaging Using a Novel Three-Dimensional Ultrasound System
JS Broder, EJ Jaffa, MR Morgan, CD Herickhoff, BP Smith, ...
Annals of Emergency Medicine 70 (4), S154-S155, 2017
12017
Covariance Decomposition of Ultrasonic Backscatter: Application to Estimation-based Image Formation
MR Morgan
Duke University, 2020
2020
Evaluation of Transplant Kidneys Using a Novel Point of Care 3D Ultrasound System.
J Salinaro, J Broder, E Jaffa, M Morgan, D Vikraman-Sushama, J Dahl, ...
AMERICAN JOURNAL OF TRANSPLANTATION 18, 823-823, 2018
2018
Notice of Removal: Swept synthetic study of large aperture imaging through ex vivo human abdominal wall
N Bottenus, W Long, M Morgan, G Trahey
2017 IEEE International Ultrasonics Symposium (IUS), 1-1, 2017
2017
Notice of Removal: Low cost 3D Doppler ultrasound: Preliminary in vivo results
MR Morgan, CD Herickhoff, JS Broder, JJ Dahl
IEEE International Ultrasonics Symposium, IUS, 2017
2017
Notice of Removal: Low-cost 3D ultrasound with any probe: A sensor-based approach
C Herickhoff, M Morgan, J Broder, J Dahl
IEEE International Ultrasonics Symposium, IUS, 2017
2017
The system can't perform the operation now. Try again later.
Articles 1–20